Indirect Diffraction Testing¶
Diffraction¶
Preparation
You need access to the ISIS data archive
osiris_041_RES10.cal
file from the unit test data
Time required 2-5 minutes
Open
Interfaces
>Indirect
>Diffraction
Make sure
Instrument
is set toIRIS
The default Detector Grouping should be
All
In
Run Numbers
enter 26176Click
Run
The output workspace should have 1 spectra
Change the Detector Grouping to
Groups
and enter 4 groupsClick
Run
The output workspace should have 4 spectra
Change the Detector Grouping to
Custom
, enter105-108,109-112
Click
Run
The output workspace should have 2 spectra
Still using
Custom
, try spectra numbers outside of the range 105-112. This should not be allowed.Using
Groups
, try more than 8 groups. This should not be allowed.Using
File
, try an empty string. This should not be allowed.
Time required 2-5 minutes
Open
Interfaces
>Indirect
>Diffraction
Make sure
Instrument
is set toOSIRIS
Set
Reflection
toDiffonly
In
Run Numbers
enter 89813In
Vanadium File
enter 89757In
Cal File
load theosiris_041_RES10.cal
file from the unit test dataSelect Detector Grouping to be
All
Click
Run
There should be three output workspaces, ending in
_dRange
,_q
and_tof
Each of the output workspaces should have 1 spectra
Change the Detector Grouping to
Groups
and enter 5 groupsClick
Run
Each of the output workspaces should have 5 spectra
Change the Detector Grouping to
Custom
, enter3-500,501-962
Click
Run
Each of the output workspaces should have 2 spectra