Updates for week 5 of 2015

  • Move direct inelastic scripts into separate package
  • Enable ExportSampleLogsToCSVFile and ExportExperimentLog to export UTC time
  • Bugfix in IntrumentView
  • Bugfix in goniometer rotation sense is not used
  • Modified FitPeaks to improve ExpectedPeak parameter for EnginX
  • Instrument definition file for HB2A
  • Nexus file-loading clean-up
  • MDWorkspaceTests, in SystemTests, fails to clean up files it creates
  • Enable LoadFullprofResolution to add Ikeda Carpenter PV parameters to workspace
  • PeakShape functionality into the PeaksWorkspaces

Detailed Merges for Jan 24 - 30, 2015

  • [#149|2f12398] Add a define for the OF macro
  • [#8172|2b99298] Nexus file-loading clean-up
  • [#8492|abc3ded] Fix unreleased use of POCO::XML document or nodelists in SINQHMListener
  • [#8959|0645e37] SaveReflCustom save Algorithm
  • [#9261|b5aaad4] Enable the GSAS instrumenent file loading algorithm to add Ikeda Carpenter PV parameters to workspace
  • [#9846|b483142] Re-insert CalMuonDeadTimeTest
  • [#10473|7265066] Multi-data set fitting interface: add optional Fit’s properties to the property browser
  • [#10605|25fdc4c] For EnginX FitPeaks improve ExpectedPeak entry
  • [#10711|27867f7] Replace Indirect Wiki pages with RST files using the interface directive
  • [#10778|4d51393] Indirect Simulation incomplete error report
  • [#10779|8b895d1] Indirect Tools no error message for nonsense chemical formula
  • [#10802|c72ea52] Data comparison UI
  • [#10803|63e7d67] Move direct inelastic scripts into separate package
  • [#10803|bd78a4b] Move direct inelastic scripts into separate package
  • [#10836|c7e45c9] Modify autoproperties to use standard system dictionary
  • [#10845|bfe3dd5] Enable ExportSampleLogsToCSVFile and ExportExperimentLog to export UTC time
  • [#10859|946f9bf] GPSANS: Add UI option to error weighting
  • [#10863|b64ee2c] Qt widget to select an indirect instrument configuration
  • [#10878|e281ef6] Peak Shape
  • [#10881|b0be876] Mover run properties to descriptor and move common run functionality to them
  • [#10881|c6d9fe4] Mover run properties to descriptor and move common run functionality to them
  • [#10928|665d271] Create instrument definition file for HB2A
  • [#10931|afab711] Fix coverity issues in instrument view pick tab
  • [#10932|3f27d38] SaveRefl ThreeColumn/Custom Ascii Documentation
  • [#10933|893cd6e] IntrumentView PickTab crashes Mantid
  • [#10952|ca7b135] SliceViewer crash
  • [#10953|72a0bd8] Tiled Window Crash
  • [#10957|f8e4428] Goniometer rotation sense is not used
  • [#10962|a6ea9d1] MDWorkspaceTests, in SystemTests, fails to clean up files it creates
  • [#10964|c0e4225] LoadParameterFile should try to get a file from the instrument directory if the absolute path is not valid
  • [#10970|c5c9352] Add MonitorsAsEvents in LoadEventNexusTest
  • [#10972|767161d] fix master_clean-clang build on Jenkins
  • [#10972|3eab1df] fix master_clean-clang build on Jenkins
  • [#10974|eaba3b7] Correct error in CalculateResolution proof
  • [#10979|b2d49e2] SuggestTIBCNCS error
  • [#10981|204a2f0] Add link in IntegratePeaksMD
  • [#10990|a593146] Fix severe warning in RefinePowderInstrumentParameters-v3.rst
  • [#10991|a712ae4] Remove bank58 from TOPAZ geometry this run cycle
  • [#10998|916870a] Valgrind Error